Herunterladen Inhalt Inhalt Diese Seite drucken

wissner-bosserhoff SafeSense Gebrauchsanweisung Seite 55

Bed-exit system
Vorschau ausblenden Andere Handbücher für SafeSense:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
a Field strength from fixed transmitters such as base stations for radio (cellular/cordless) telepho-
nes and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot
theoretically be predicted with accuracy. To assess the electromagnetic environment due to fixed RF
transmitters, an electromagnetic site survey should be considered. If the field strength measured at
the location where the SafeSense
the product should be monitored to verify that it is functioning as intended. If unusual performance
is observed, additional steps may be required such as a change in orientation or a different location
for the system.
b For frequencies between 150 kHz and 80 MHz, the field strength should be lower than 3 V/m.
Table 4: Recommended safety distances between portable and mobile RF telecommunications
equipment and ME equipment or ME system - for ME equipment or ME systems that are not
life-supporting
Recommended separation distances between portable and mobile RF telecommunications devices
and the SafeSense
Bed-Exit System.
®
The SafeSense
Bed-Exit System is intended for operation in an electromagnetic environment where
®
RF interference is controlled. The customer or SafeSense
gnetic interference by maintaining the minimum distance between portable and mobile RF telecom-
munications devices (senders) and the Bed-Exit System, depending on the communications device's
power output as specified below.
Rated maximum output
power of transmitter [W]
0,01
0,1
1
10
100
For transmitters rated at a maximum output power not listed above, the recommended separation
distance d in meters (m) can be estimated using the equation applicable to the frequency of the
transmitter, where P is the maximum output power of the transmitter in watts (W) according to the
manufacturer.
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies
NOTE 2: These guidelines may not apply in all situations.
Electromagnetic propagation is affected by absorption and reflection from structures, objects
and people.
Bed-Exit System is used exceeds the above compliance levels,
®
Separation distance according to frequency of transmitter [m]
150 kHz to 80 MHz
d=0,35*√P
0,12
0,37
1,17
3,69
11,67
user can therefore help to avoid electroma-
®
80 MHz to 800 MHz
d=0,35*√P
0,12
0,37
1,17
3,69
11,67
800 MHz to 2,7 GHz
d=0,35*√P
0,23
0,74
2,33
7,38
23,33
55

Werbung

Inhaltsverzeichnis
loading