3.2 Maintenance schedule
It is imperative that the service intervals be adhered to! Confirm with the relevant key when comple-
ted. Switch on the ignition!
Ser-
Appears
vice-
Once
Cyclically
code
with Oh
Ev. No.
Oh
6000
Commiss.
0
6000
Approx. 50
5
6001
10
0
6002
100
0
6003
500
0
6004
500
0
6005
500
1500
0
6006
500
1000
0
6107
1500
3000
0
6008
1500
3000
0
6009
4500
0
Service work
Ev. No.
Sld
st
1
inspection
Docket A (see maintenance booklet)
Docket B (incl. docket A)*
Docket C (incl. dockets A and B)*
360
Change engine oil
Change gearbox oil
360
Bio hydraulic oil analysis (test kit order no.
2999737)
720
Change hydraulic bio oil)
720
Change the hydraulic mineral oil)
1800
Change toothed belt/tension pulley
97
3.2 Wartungsplan
Confirmation by Keys
ATLAS engineer
ATLAS engineer
Driver
Operator
A
/
Driver
Operator
B*
/
ATLAS engineer C + A*
Own engineer
C + A
ATLAS engineer C + A
Driver
Operator
C + A
/
ATLAS engineer C + A
ATLAS engineer C + A
ATLAS engineer C + A