(17)
(18)
32
Special conditions for safe use:
-
In dust explosive areas (IIIA, IIIB, IIIC) zone 20 and in gas explosive areas (IIC) with zone 0 the
models with display and the models with M12 connections must not be used.
-
The plastic filter caps must not be used in gas explosive areas of group IIC in zone 0.
-
The sensor element must be covered with one of the provided filter caps.
-
The sensor pipe of the remote probe is not electrically conductively connected with the housing
of the main unit and must therefore be grounded separately. In addition, in potentially explosive
areas of zone 0, the cable to the remote sensor must be installed in a metallic and earthed
conduit.
-
The configuration and adjustment of the EE300Ex is only permitted with the associated
HA011068 connection cable outside the hazardous area. When the HA011068 is connected to
the EE300Ex, CH1 and CH2 must not be connected.
-
In case of optional use of the second measuring channel, both channels must be galvanically
isolated from each other.
Essential health and safety requirements:
met by standards
According to article 41 of Directive 2014/34/EU, EC-type examination certificates which have been
issued according to Directive 94/9/EC prior to the date of coming into force of Directive 2014/34/EU
(April 20, 2016) may be considered as if they have been issued already in compliance with Directive
2014/34/EU. By permission of the European Commission supplements to such EC-type examina-
tion certificates and new issues of such certificates may continue to hold the original certificate
number issued before April 20, 2016.
This EU-type examination certificate according to Directive 2014/34/EU is a new issue of the EC-
type examination certificate according to Directive 94/9/EC dated from 2013-03-05, including the
1
supplement dated from 2014-04-16, Issue 01 dated from 2019-09-30 and todays additional
st
changes. Details are recorded in the confidential report 713215990.
EU-Type Examination Certificate without signature shall not be valid. The certificates may be circulated only without altera-
tion. Extracts or alterations are subject to approval by TÜV SÜD Product Service GmbH.
The document is internally administrated under the following number: EX5A 038892 0010 Rev.01
TÜV SÜD Product Service GmbH • Zertifizierstelle • Ridlerstraße 65 • 80339 München • Deutschland
In case of dispute, the German text shall prevail.
Bedienungsanleitung EE300Ex Feuchte / Temperatur Sensor