Correct Usage / Operational Conditions

Use the tubular motors only to open and close roller
blinds and awnings.
The use of the wrong tubular motors or components
can lead to property damage.
◆ The motor cable must be run inside the empty tube,
in compliance with the local electrical codes, to the
junction box.
◆ For motor types with PVC connecting cable (see page
28, Technical data), the connecting cable is to be
protected by a suitable, earthed empty tube if used
outside.
◆ Use only original components and accessories from
the manufacturer.
◆ Only use tubular motors which correspond to the
local conditions in terms of their power. Incorrectly
dimensioned tubular motors can lead to damage:
> An insufficiently dimensioned tubular motor can
be damaged due to overloading.
> An excessively dimensioned tubular motor can,
for example, cause damage to the roller shut-ter
or roller shutter box in self-learning mode.
◆ Consult a specialist dealer when selecting a tubular
motor and observe the corresponding tractive force
specifications on our website: www.rademacher.de.
i

Improper use

Using the tubular motors for purposes other than previously
mentioned is impermissible.
Never use the tubular motor in systems with in-
creased safety-relevant requirements or where there
is an increased risk of accidents.
◆ Such applications require additional safety equip-
ment. Observe the respective statutory regulations
for the installation of such systems.
i

Required expert knowledge of the installer

The installation, electrical connection and maintenance
must be carried out by a qualified person with appropriate
training or by a specialist roller shutter firm in accordance
with the instructions in this manual.
DE EN NL FR IT ES
Operational Conditions
◆ For the electrical connection, a 230 V/50 Hz power
drop must be continuously available at the installation
site, with a disconnect device (cut-out) provided by
the customer.
◆ The roller shutter must run up and down smoothly. It
should not jam.
Never use the tubular motor in continuous operation.
Doing so will cause serious damage.
Never use the tubular motor for shutters with
openings of ≥ 50 mm in diameter.