Herunterladen Inhalt Inhalt Diese Seite drucken

Installing The Extension Piece; Technical Data - Endress+Hauser Promag 35S Einbauanleitung

Installing extension pieces converting promag 35s to promag 55s
Vorschau ausblenden Andere Handbücher für Promag 35S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7

Installing the extension piece

When converting from the Promag 35S with hard rubber lining to the
Promag 55S with PU lining:
Do not use a seal between the sensor and extension piece!
• The extension piece is not lined.
• The extension piece must be mounted in the direction of flow and downstream from
the sensor on the outlet side.
• When installing the extension piece, make sure that the lining on the sensor flange is
not damaged.
• Use a seal with a thickness of 2 mm (0.079 in) between the pipe flange and the
extension piece.
• Ensure that the seals do not protrude into the pipe cross-section.
1
Nut
2
Extension piece
3
Seal
4
Screw
7.1

Technical data

Material: 316L/1.4571
Endress+Hauser
1
2
3
4
EA00052D