Conversion Instructions
Proline Promag 55S
Conversion transmitter Promag 55 compact version to Promag 55 remote version
EA00069D/06/A2/03.09
71086296
Determining the correct spare part set
This method is used merely to determine whether the set/part is suitable for the measuring device. Other conclusions drawn from the table are not applicable.
1. Read the order code from the nameplate on the measuring device and enter it in the empty fields below.
2. Select the order number of the set /part in the table below.
3. Check the fields after the order number selected against the highlighted items in the order code.
If each field after the selected order number contains a digit or letter from the order code, the set/conversion kit can be used for the measuring device
(* = no restriction).
The conversion kit contains only parts for the conversion.
These instruction apply to the following conversion kit and type of device:
Order number, conversion kit
1 × connection housing premounted (including connection board and connection label)
1 × conversion kit cable entry Promag electronics compartment NPT ½"
1 × conversion kit cable entry Promag electronics compartment G ½"
DK5UP6
1 × conversion kit cable entry Promag electronics compartment M20 × 1,5
1 × notice label for the sensor
1 × form "data storage"
1 × conversion instruction
Determining approval and authorized personnel category:
1. Take the option from the order code field highlighted in gray.
2. Determine the approval and authorized category of personnel using the option in the table.
3. Any person who carries out conversions is responsible for safety during the work, the quality of work completed and safety of the device after conversion.
Approval
Option Position 12
Competence level
1 = Trained specialist at customer site, 2 = Service technician authorized by Endress+Hauser, 3 = Endress+Hauser Flowtec AG (return device)
The transmitter for the conversion has to be ordered seperatly. Only transmitter with the following order code can be used:
1
Order-Code
5
Transmitter Promag
Tool List:
8 mm, 22 mm
3 mm
1 Information about the modified device
Relevant documentation
The new documentation, delivered with the transmitter will be relevant.
1
2
Promag
5 5 S * * – * * * * *
without approval
A
2, 3
2
3
4
5
5
X
X
X
0.5 × 3.5 mm
3
4
5
6
7
8
FM/CSA Div. 2
R
2, 3
6
7
8
9
–
X
X
X
T20
PH2
9
10
11
12
13
14
* * * * *
A, R
A, P, 1
10
11
12
13
14
X
X
A, R
C, S, R
side cutter
15
16
17
18
other approval
not available
15
16
17
18
*
*
*
*
*
pen/ tool
Ø < 2 mm
(0.08 inch)