no signa l-c ont a c t m onit or e nvm -re m ova l
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor envm-removal
3 8 .1 .5
signa l-c ont a c t m onit or t e m pe ra t ure
Sets the monitoring of the device temperature.
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor temperature
Parameter Value
signal contact no.
P-1
no signa l-c ont a c t m onit or t e m pe ra t ure
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor temperature
3 8 .1 .6
signa l-c ont a c t m onit or pow e r-supply
Sets the monitoring of the power supply(s).
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor power-supply <P-2>
Parameter Value
signal contact no.
P-1
1..2
P-2
no signa l-c ont a c t m onit or pow e r-supply
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor power-supply <P-2>
3 8 .1 .7
signa l-c ont a c t st a t e
Configure the Signal Contact manual state (only takes immediate effect in manual mode).
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> state <P-2>
Parameter Value
signal contact no.
P-1
open
P-2
close
3 8 .1 .8
signa l-c ont a c t t ra p
Configure if a trap is sent when the Signal Contact changes state (in monitor mode).
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> trap
Parameter Value
signal contact no.
P-1
no signa l-c ont a c t t ra p
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> trap
138
Meaning
Meaning
Number of power supply.
Meaning
Open the signal contact (only takes effect in the manual mode).
Close the signal contact (only takes effect in the manual mode).
Meaning