3 6 Se lft e st
3 6 .1
se lft e st
Configure the selftest settings.
3 6 .1 .1
se lft e st a c t ion
Configure the action that a selftest component should take.
Mode: Global Config Mode
Privilege Level: Administrator
Format: selftest action <P-1> <P-2>
Parameter Value
task
P-1
resource
software
hardware
log-only
P-2
send-trap
reboot
3 6 .1 .2
se lft e st ra m t e st
Enable or disable the RAM selftest on cold start of the device. When disabled the device booting time is reduced.
Mode: Global Config Mode
Privilege Level: Administrator
Format: selftest ramtest
no se lft e st ra m t e st
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no selftest ramtest
3 6 .1 .3
se lft e st syst e m -m onit or
Enable or disable the System Monitor 1 access during the boot phase. Please note: If the System Monitor is
disabled it is possible to loose access to the device permanently in case of loosing administrator password or mis-
configuration.
Mode: Global Config Mode
Privilege Level: Administrator
Format: selftest system-monitor
no se lft e st syst e m -m onit or
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no selftest system-monitor
3 6 .1 .4
se lft e st boot -de fa ult -on-e rror
Enable or disable loading of the default configuration in case there is any error loading the configuration during
boot phase. If disabled the system will be halted.
Mode: Global Config Mode
Privilege Level: Administrator
Format: selftest boot-default-on-error
no se lft e st boot -de fa ult -on-e rror
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no selftest boot-default-on-error
134
Meaning
Configure the action for task errors.
Configure the action for lack of resources.
Configure the action for broken software integrity.
Configure the action for detected hardware errors.
Write a message to the logging file.
Send a trap to the management station.
Reboot the device.