Herunterladen Inhalt Inhalt Diese Seite drucken

Geberit ESG 3 Betriebsanleitung Seite 42

Vorschau ausblenden Andere Handbücher für ESG 3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN
Fault
LED displays for
<Mains
connection>
<Ready for
welding>
<Welding
complete>
light up, and
<General
malfunction> LED
display
1) For addresses of qualified service centres, contact your Geberit sales
company or visit www.geberit.com
42
Cause
Sleeve connection
plugs worn or too
many interruptions
,
from removing the
sleeve connection
and
plugs during
welding procedure
flashes
Actions
Disconnect the mains
plug
Visually inspect the
sleeve connection plugs
and sleeve connection
cables if necessary, or
replace the connecting
cables
Send the electrofusion
machine to a qualified
service centre
B1157-002 © 01-2015
1)
966.475.00.0 (01)