Malfunction
−
Leakage of grease at the
EN
pressure relief valve
−
The red indicator pin at the
malfunction indicator of the
pump element is visible
−
The LEDs in the inspection
window of the control flash
46
−
Level error, although the
reservoir is filled with
lubricant
−
Level error although there
is no level monitoring in the
pump
− The pump function (pump
operating time or cycle
time) does not correspond
to the values adjusted in
the inspection window of
the control unit
BEKA 2016 All rights reserved!
...a product of BEKA
Cause
−
Excessive pressure in the
system
−
Progressive distributor
blocked
−
System blocked
−
Defective valve spring
−
Excessive system pressure
−
Pump lubricates
−
Grease level error
−
Excessive pressure error
−
Speed error
−
Stroke error
−
CPU/memory error
−
Capacitive proximity switch
in the reservoir defective
−
Cable of the level
monitoring defective
−
Level monitoring activated
in the control unit
−
The operating mode or the
adjustment range of the
control has been changed,
but the sticker in the
inspection window not
−
Check the system
−
Replace distributor
−
Repair blocked bearing
point
−
Renew the pressure relief
valve
See „Leakage of grease at
−
the pressure relief valve"
−
No error (see signals)
−
Fill reservoir
−
Check the system and
repair it, if necessary
−
Check the system and
repair it, if necessary
−
If there is no
defectiveness, activate
intermediate lubrication
once or twice
−
Exchange the control unit
−
Send the lubricant
reservoir with level
monitoring in for being
repaired
−
Exchange the cable
−
Deactivate level monitoring
in the control unit with the
system diagnosis software
BEKA-DiSys
− Make a diagnosis with the
diagnosis software
− BEKA-DiSys
− Adapt the adjustment to
the sticker in the
inspection window or
exchange the sticker