15. Ventilation of the pump:

If the lubricant reservoir has been emptied completely by mistake, it may be necessary to
ventilate the pump.
To do so, proceed as follows:
1. Unscrew main line from pump outlet.
EN
2. Trigger additional lubrication pulse until lubricant comes out of the pump outlet without air
inclusions.
3. Reconnect main line.
4. Trigger additional lubrication pulse.

16. Service and maintenance:

All components of the grease central lubrication pump are maintenance-free.
Cleaning in washing plants or with steam jet devices (minimum distance 40 cm) is permitted.
34
Nevertheless should a visual inspection be carried out in regular intervals:
− Check the level
− Check the condition of the electrical lines (electric main, connection cables to the
progressive distributor, etc.)
− Check the electrical connections (connectors)
− Check the perfect function of the control unit by triggering an intermediate lubrication
− Only replace defective fuses by equivalent ones
− Check all components for leakages or damages every four weeks.
Attention!

17. Disposal:

Note!
BEKA 2016 All rights reserved!
...a product of BEKA
Ensure that the current supply is deactivated (ignition off) before doing
maintenance works at the pump. Clean soiled or contaminated surfaces
before the maintenance work and wear protective cloths if necessary.
All further works may only be carried out by the staff of BEKA or by staff
trained by BEKA.
The waste disposal advice of the well fluid manufacturer must be heeded
when changing lubricant!
Observe the regional valid regulations concerning the disposal of the
grease lubrication pump.