With switched on ignition an intermediate lubrication can any time be initiated by actuating the
button at the side of the pump. The pump immediately starts with lubrication then. The remaining
cycle time or lubrication time is reset and starts from the beginning again.
You can reset a malfunction by pressing the button for intermediate lubrication. The pump then
tries to start a new lubrication process again.
Control by time
Green LED for indication of the function
With the mode time control can lubrication time and cycle time be adjusted.
Control by revolutions:
With the control by revolution is the lubrication duration determined by the number of revolutions
of the pump motor.
The pump motor is connected to the control unit via sliding contacts. The control unit receives a
signal with each motor revolution.
11.1.2.

Operating mode cycle control:

At the sequential control is the number of piston strokes of the
progressive distributor counted, in order to determine duration of
the lubrication period.
To this purpose is a proximity switch mounted at the progressive
distributor, which is connected to the control unit (see terminal
diagram on page 15). A signal is sent to the control unit with each
piston stroke.
Technical data of the proximity switch:
Operating voltage:
Connection method:
(normally open contact)
Power rating:
Connection:
4 poles, M12x1 pluggable
Red LED for indication of malfunctions
10 to 60 V DC
Function display:
PNP-NO
Housing material:
Protection class of switch:
200 mA
Ambient temperature range:-40° C to +85° C
Button for activating
intermediate lubrication
Progressive distributor
Proximity switch
BEKA 2016 All rights reserved!