21. Malfunction - Cause - Remedy:
Malfunction
− Pump does not operate
− Pump operates, but does
not supply lubricant
−
No grease collar at all
lubrication points
−
No grease collar at several
lubrication points
− No grease collar at one
lubrication point
−
Reduced pump speed
Cause
− Fuse of unit blown
− Integrated electronic
control defective
− Electrical cable broken
− Pump defective
− Pump element not nested
− Air in the feed piston
− Filling level below
minimum
− Defective pump element
− Pump does not operate
−
Cycle time too long
− Lubrication time too short
− Number of strokes too low
− Number of rotation too low
− Pump element PE-120 V
adjusted too low
− System blocked
− Feed pipes for secondary
distributors burst or leaky
− Fitting leaky
− Appropriate lubrication line
burst or leaky
− Fitting leaky
− High pressure in the
system
− Low ambient temperature
Remedy
−
Replace fuse
−
Replace integrated control
−
Renew electrical cable
−
Replace the pump
−
Renew pump element
−
Ventilate the pump
−
Re-fill the reservoir
−
Renew pump element
−
See „Pump does not
operate"
−
Reduce cycle time
−
Increase lubrication time
−
Increase number of
strokes
−
Increase number of
rotations
−
Adjust pump element
See „Leakage of grease
−
at the pressure relief
valve"
−
Renew the pipe
−
Re-tighten or renew the
fitting
−
Renew the pipe
−
Re-tighten or renew the
fitting
−
Check system / bearing
points
−
Not defectiveness
(1 or 2 intermediate
lubrication cycles might be
useful)
BEKA 2016 All rights reserved!
EN
45