Herunterladen Inhalt Inhalt Diese Seite drucken

Micro Switch At The Pressure Relief Valve - MBZ EP-1 Original - Betriebs- Und Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Wiring diagram with supply voltage of 90-250 V AC:
Technical data:
Supply voltage:
Connecting method:
Switching current:
Protection class:
Ambient temperature range:
9.3.3. Micro switch at pressure relief valve:
The micro switch at the pressure relief valve is used for
monitoring the maximum operating pressure in the central
lubrication system.
If a malfunction occurs in the system, the micro switch is
actuated.
The micro switch signal can be processed by any already
existing signal encoder, e. g. an on-board controller, or by
an external or integrated control unit.
The lubricant comes out under high pressure (250 bar)!
Wear safey goggles and also do not stay otherwise within the area of the pressure
relief valve in the case of a malfunction of the central lubrication unit!
Never work when the voltage (ignition) of central lubrication system or pump is
connected! Relieve the central lubrication system before you start the works!
Terminal diagram for connecting the micro switch
to an external control unit:
Apparent ohmic
resistance
NO (normally open
contact)
NC (normally closed
contact)
brown
blue
brown
L1
blue
Q
at 70°C:
switch:
plug:
black
blue
brown
P
black
Pole assignment:
Compact plug connection, 3 poles+ PE
No. 1 = L1
No. 2 = free
No.3=Q
= yellow/green (only for max.)
90 to 250 V AC
NO contact (Tyristor outlet)
min. 5 mA
max. 250 mA
IP 67
IP 54
-25°C to +70°C
Technical data:
Supply voltage:
max. current load:
Contact type:
Temperature range:
Protection class:
Connection:
Micro switch
10 to 60 V DC
I = 1,7 A
1 changeover switch
-25° C to +85° C
Cable, length 0.5 m, welded
BEKA 2016 All rights reserved!
EN
19
IP 67

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Fkggm-ep dcFkggm-ep

Inhaltsverzeichnis