Adjusting the delivery rate:
−
All pump elements are set to full stroke by the manufacturer.
−
Remove screw plug (2) with Allen key (A/F 5).
−
Set screw (3) can be turned with a screwdriver.
−
Turning clockwise reduces the output rate.
−
Turning counter-clockwise increases the output rate.
−
Maximum stroke of set screw is 2.4 mm = 6 notches.
−
1 turn of set screw is 0.8 mm = 2 notches.
−
Tighten screw plug (2) incl. sealing ring.
10.3. Installation and removal of the pump elements:
−
Only install / remove when pump is off.
−
Install pump element with partially extended piston (4) and insert it at an angle into the housing
drilling(see diagram A).
−
When the piston head rests on pressure ring - move element into vertical position (see
diagram B).
−
Piston head must run in guide ring groove.
−
Tighten the pump elements.
−
For removal, reserve above sequence.
−
When removing the pump element, ensure that the piston (4) is not left behind in the pump
housing.
Diagram A:
4
The pump element or the pump are destroyed at first operation, if the pump
Attention!
element has not been positioned correctly.
10.4 Ventilation of the pump
- Remove screw plug (2) with Allen key (A/F 5).
- Screw the adjusting screw (3) by means of a screw driver until stop
- Start the pump
- Screw back the adjusting screw (3) by 1 notch per revolution of the agitator blade
- Operate the pump until oil comes out of the screw plug thread
- Assemble the screw plug (2) incl. sealing ring and tighten it
Diagram B:
2
BEKA 2016 All rights reserved!
EN
21