11.1.3. Special equipment
Internal memory:
The below listed values are saved at the control unit BEKA-troniX1. They can be read out or
changed with the diagnosis software BEKA-DiSys:
Controlling type
Version of control unit
EN
Serial number
Manufacturing date
Operating mode
Set parameters (adjusting ranges)
The control unit EP-tronic additionally saves the following values:
RTC (Real-Time-Clock) date and time, also adjustable for other time zones
Operating hours
Running time of the pump
Number of intermediate lubrication
Number of filling errors
Number of excess pressure errors
Number of stroke monitoring errors
Number of revolution monitoring errors
Date and time of last diagnosis
Number of total diagnosis
List of the last 100 errors with error type, as well as indication of time and date
24
List of the last 100 changes of the adjustment with time and date
For a modification of the above mentioned values is the diagnosis software BEKA-DiSys as well
as a data cable necessary (see description BEKA-DiSys).
11.1.4. Adjustment of the operating mode and the adjustment ranges:
The modes and the adjusting ranges can be changed by means of the diagnostic software
BEKA-DiSys.
All adjusting ranges for the lubrication time can be combined with all cycle time ranges.
Adjusting ranges BEKA-troniX1:
Lubrication times:
1 to 16 min. (16 notches every 1 min.)
2 to 32 min. (16 notches every 2 min.)
2 to 32 sec. (16 notches every 2 sec.)
Revolutions of the pump:
1 to16 revolutions (16 notches every 1 revolution)
10 to 160 revolutions (16 notches every 10 revolutions)
170 to 320 revolutions (16 notches every 10 revolutions)
BEKA 2016 All rights reserved!
...a product of BEKA
Cycle times:
0.5 to 8 h (16 notches every 0.5 h)
2 to 32 min. (16 notches every 2 min.)
2 to 32 h (16 notches every 2 h)