Status codes

8
Status codes
Tab. 11: Status codes
Code (decimal)
Meaning
00
OK
03
Controller failure
06
Battery Failure
08
Primary Cable Grounding (Over Current or Earth Fault)
09
Current XFMR Cable Break
11
SCR / Transistor Short (with "Weld without command" relay)
13
High current
15
ISO contactor fault:
ISO contactor not opened (with "Weld without command" relay)
17
Low Line Voltage
18
High Line Voltage
21
Emergency Stop
22
Memory Data Error
23
SCR / Transistor Overtemp
25
Pilot Invalid
27
No Stepper Reset
28
Station water flow fault
29
Tip water flow fault
30
Other fault
31
Half cycling
32
Low current / MC Fault
35
External no weld
40
ISO contactor fault:
ISO contactor not closed (without "Weld without command" relay)
ISO contactor not opened (with "Weld without command" relay)
46
End of stepper
47
Re-Weld done
51
I-Available low/high
60
PSF Fault
61
UIP too high / too low
62
Resistance too high / too low
63
Electrode voltage measuring circuit error
64
Weld time exceeded
66
Q Stop component
67
Q Stop program
71
High motor current
72
No motor current