Bosch Rexroth AG
Features
Serial inputs 1.05 = „PS Input"
Serial input 1.06 – 1.11 = „Stepper #x
Serial Input 1.12 = „NTSR"
Discrete Input E_02 = „NTSR"
Serial Input 1.13 = „DTSR"
Discrete Input E_03 = „DTSR"
• Weld schedules parameter Weld On/Off (Program)
• Global Schedule Parameter Weld/ No Weld (Timer)
• Weld complete
This Input will start that Weld Schedule, which is selected at the Serial Inputs 1.14
to 2.05
Discrete electrode number
(Reset)"
At these Inputs an Electrode Number will be assigned to the Inputs "NTSR – New
Tips Reset" i.e. to reset electrode #3, tips have been changed
• Serial input 1.06 = "Stepper #1 (Reset)" = off =0
• Serial input 1.07 = "Stepper #2 (Reset)" = off =0
• Serial input 1.08 = "Stepper #3 (Reset)" = on =1
• Serial input 1.09 = "Stepper #4 (Reset)" = off =0
• Serial input 1.10 = "Stepper #5 (Reset)" = off =0
• Serial input 1.11 = "Stepper #6 (Reset)" = off =0
• Serial input 1.12 = "NTSR"
• Serial input 1.13 = "DTSR"
At these Inputs an Electrode Number will be assigned for use with Input "DTSR –
Dressed Tips Reset" i.e. to reset electrode #3, tips have been dressed
• Serial input 1.06 = "Stepper #1 (Reset)" = off =0
• Serial input 1.07 = "Stepper #2 (Reset)" = off =0
• Serial input 1.08 = "Stepper #3 (Reset)" = on =1
• Serial input 1.09 = "Stepper #4 (Reset)" = off =0
• Serial input 1.10 = "Stepper #5 (Reset)" = off =0
• Serial input 1.10 = "Stepper #6 (Reset)" = off =0
• Serial input 1.12 = "NTSR"
• Serial input 1.13 = "DTSR"
• Serial input 2.14 = "Tip Dress Motor"
If Stepper #1 thru 6 are off, then NTSR and DTSR will reset all heat steppers.
Inputs operate in parallel
Indication, that the Tips, selected by Electrode Number, have been changed.
Selected Counter is reset to "0".
Serial Output 1.02 "Maintenance Required" is turned off.
Serial Output 1.04 "New Tip" is turned on.
Serial Output 1.04 "New Tip" will stay on until receipt of next Binary Pilot signal.
Inputs operate in parallel
Indication, that the Tips, selected by Electrode Number, have been dressed.
Selected Counter is reset to "0".
Serial Output 1.02 "Maintenance required" is turned off
Serial Output 1.05 "Dressed Tip" is turned on.
Serial Output 1.05 "Dressed Tip" will stay on until receipt of next Binary Pilot
signal.
R911172797 | PSI 6xCx.775
= off (on)
= on (off)
= off = 0 Fault: "Internal No Weld"
= on =1
= off =0
= off =0
= on =1
= off = 0