Herunterladen Inhalt Inhalt Diese Seite drucken

Discrete Outputs - Bosch Rexroth PSI 6 C 775 Serie Typspezifische Anleitung

Mittelfrequenz-umrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

72/78
Bosch Rexroth AG
Features
Serial output 3.04 = „Free"
Serial output 3.05 = „Adaptive Mode
Serial output 3.06 = „COMM OK"
Serial output 3.07 = „Q-Stop"
Serial output 3.08 = „Acknowledge End
Of Component"
Serial output 3.09 = „UI Monitoring"
Discrete output A_01 = „Close Weld
Discrete output A_02 = „Magnet Valve"
Discrete output A_03 = „Tip Dress
Discrete output A_04 = „Free"
Discrete output A_05 = „Intensify"
Discrete output A_06 = „Free"
Discrete output A_07 = "VS1 – SVCR"
Discrete output A_08 = "VS2
(reserved)"
Discrete output A_09, A_10, A_12,
A_16 = "VS3 – VS 6 Binary Pressure
Select 1-8 (reserved)"
Discrete output A_17 = "DIO OUT 1 –
Tip Dress Motor On"
Free.
The current operating Weld Schedule is running in Adaptive Regulation.
Enabled"
Output stays high until binary pilots call a schedule which has not the adaptive
mode enabled then the output goes low. If binary pilots call a schedule which has
the adaptive mode enabled, the output goes high.
Adaptive mode enabled means that adaptive regulation and monitoring are both
active for the actual schedule called by the binary pilots. The weld control only
sets the output high or low – no fault message.
Signal is always On.
The current operating Weld Schedule is running in Adaptive Monitoring.
This Output is used for the Q-Stop functionality. (Details for Q-Stop refer to Tab1.
Required and supplementary documentation, UI regulation and monitoring).
The current operating Weld Schedule is running in Adaptive Monitoring.
7.1.4

Discrete outputs

See Isolation Contactor Control.
Contactor"
This Output will be activated at the beginning of the Pre-Squeeze Time and will
be deactivated at the end of the Hold Time.
In "Ethernet IP" Mode this output is controlled by serial input 2.14 "Tip Dress
Motor On"
Motor On".
A03 = Serial Input 2.14.
In "RS485" Mode this output is set to "0".
Free.
This is the same function as serial output 3.03 = "Intensify".
Free.
Equal to serial output A_00 = "In Weld Cycle".
Reserved for pneumatic retract cylinder on pneumatic weld gun.
No Function at this time.
No Function at this time -Used for Air Guns only.
This output is controlled by serial input 2.09 "DIO OUT 1 – Tip Dress Motor On".
A_17 = Serial Input 2.09.
R911172797 | PSI 6xCx.775

Werbung

Kapitel

Inhaltsverzeichnis
loading