R911172797 | PSI 6xCx.775
Discrete input E_07 DIO OUT 1 –
XFMR Temp
Discrete input E_08 DIO OUT 2 –
Servo Gun Temperature
Discrete input E_09 = WF2 Station
Water Flow Switch
Discrete input E_10 = WF4 Tip Water
Flow Switch
Discrete input E_11 – E_12 = „Free"
Discrete input E_13 = „Motor current
Discrete input E_14 = „Motor current
Discrete input E_15 = „Motor current
Discrete input E_16 – E_24 = „Free"
Serial Output 2.07 = Discrete Input E_07.
• The Input E_07 is active only when RS485 is selected (See E_25 IO mode)
• In case of Ethernet IP mode, Serial Output 2.07 is set to 0.
Serial Output 2.08 = Discrete Input E_08
• The Input E_08 is active only when RS485 is selected (See E_25 IO mode).
• In case of Ethernet IP mode, Serial Output 2.08 is set to 0.
• On = Proper Water flow
• Off = No Water flow
The input is monitored outside of a weld sequence. If it is off, the error "No cool
water circulation" occurs. This fault is Auto Reset.
As soon as the water flows again (input goes high) the fault is reset.
If this input is off the next pilot binary is inhibited. The fault is not automatically
reset by the next binary pilot. This input is only active when RS485 is selected
(See E_25 IO mode).
When Ethernet IP is selected, this input is maintained as a logical 1.
• On = Proper Water flow
• Off = No Water flow
The input is monitored outside of a weld sequence. If it is off, the error "No cool
water circulation" occurs. This fault is Auto Reset.
As soon as the water flows again (input goes high) the fault is reset.
If this input is off the next pilot binary is inhibited. The fault is not automatically
reset by the next binary pilot. This input is only active when RS485 is selected
(See E_25 IO mode).
When Ethernet IP is selected, this input is maintained as a logical 1.
Free.
See 7.1.8 Tip Dress Motor Current Supervision.
low"
See 7.1.8 Tip Dress Motor Current Supervision.
ok"
See 7.1.8 Tip Dress Motor Current Supervision.
high"
Free.