Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

DIsPLAy
OFF
Stove off
sTArT
The start-up phase is in progress
PeLLeT FeeDINg
Continuous pellet feeding is in progress during the ignition phase
IgNITION
The ignition phase is in progress
sTArT-uP
The start-up phase is in progress
WOrK
The normal work phase is in progress
MODuLATION
The stove is working at minimum
burN POT
Automatic burn pot cleaning is in progress
CLeANINg
FINAL CLeANINg
The final cleaning is in progress
Stove off waiting for re-ignition due to an external thermostat
sTAND-by
The stove will only re-start when the external thermostat makes a request
A new ignition is attempted when the stove has just been switched off. When the stove switches off, one
COOLINg
must wait for the complete shutdown of the fumes motor, then clean the burn pot. The stove can only be
sTAND-by
re-ignited when these operations have been performed.
Stove off due to water temperature over set
hOFF
As soon as the water temperature drops below the pre-set parameters, the stove will switch back on
bLACK OuT
The stove is cooling after a power cut.
sTAND-by
Once cooling is completed it will re-start automatically
The anti-freeze function is in progress as the H2O t° is below the factory set threshold
ANTI-FreeZe
the pump is active until the water reaches the pre-set factory parameter +2°C
The pump antilock function is in progress (only if the stove has been in an OFF state for at least 96 hours);
ANTILOCK
the pump is activated for the time pre-set by the manufacturer, in order to prevent it from blocking
AuTO bLOW
The automatic blow is active
exChANger bLOCK
Automatic exchanger cleaning is blocked