OPerATION AND LOgIC

IgNITION
Once the points listed previously have been checked, press key 1 for three seconds to ignite the stove.
15 minutes are available for the ignition phase. After ignition and having reached the control temperature, the stove interrupts
the ignition phase and passes to STARTING.
sTArTINg
During the start-up phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and pass on to
WORK.
WOrK
During the work phase, the stove reaches the set power; see following item.
ADjusTINg POWer seTTINg
Set the operating power (from 1 to 5) .
Power 1 = minimum level - Power 5 = maximum level.
h2O TeMPerATure seT ADjusTMeNT
Set the boiler temperature from 65 - 80°C .
PuMP OPerATION
The pump activates water circulation when the t° of the water inside the stove reaches 60°C. As the pump always functions
above 60°, an always open heating area is recommended to make product functioning homogenous, preventing overheating
blocks. Normally this area is defined "Safety zone".
burN POT CLeANINg
At pre-set intervals the stove performs burn pot cleaning, switching the machine off.
When the cleaning phase is finished, the stove will re-start automatically and continue its work going back to the selected
power level.
MODuLATION and h-OFF
As the water temperature approaches the set point, the boiler starts to modulate automatically bringing itself to the minimum
power.
If the temperature increases beyond the set point, it will automatically switch off indicating h-OFF and will automatically go
back on when the temperature drops below the set point.
sWITCh-OFF
Press key 1 for three seconds.
When the operation has been performed, the appliance automatically enters the switch- off phase, blocking the supply of
pellets.
The flue gas exhaust motor will remain on until the stove temperature has dropped below the factory parameters.
re-IgNITION
The stove can only be re-ignited automatically or manually when the cooling cycle conditions and the preset timer have been
satisfied.
NO IgNITION
FIrsT IgNITION COuLD eVeN FAIL As The Auger Is eMPTy AND Is NOT ALWAys AbLe TO LOAD The burN POT
WITh The requIreD AMOuNT OF PeLLeTs ON TIMe TO reguLArLy sTArT The FLAMe.
WAIT FOr The MAChINe TO COOL DOWN (greeN sCreeN)
Š
Press Key 1 FOr 3 seCONDs
Š
IF The PrObLeM OCCurs AFTer ONLy A FeW MONThs WOrKINg, CheCK ThAT rOuTINe CLeANINg sTATeD IN
The sTOVe bOOKLeT, hAs beeN CArrIeD OuT COrreCTLy.