Herunterladen Diese Seite drucken

Device Description - Kärcher IVR-L 200/24-2 Tc Dp Bedienungsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Safety instructions
WARNING
● The device is not suitable for vacuuming
up dusts that are harmful to human
health.
● Protect the device from rain. Do not store
the device outdoors.
● Every time before use, check whether the
equipotential bonding conductors (earth-
ing conductors) are connected.
CAUTION
● Switch off the device after each use and
remove the mains plug.
ATTENTION
● Only use the device indoors.
● Risk of crushing! Wear gloves when re-
moving or installing the suction head, fil-
ter inlay or collection container.
● Risk of damage! Never vacuum without a
filter or with a damaged filter.
● Wear safety shoes when operating the
device.
● Only move the device at walking speed,
and to move down a decline, have two
workers steady the device as necessary.
● Be careful to ensure that there is no dust
spillage when replacing accessories.
Device with tilting chassis (Tc)
ATTENTION
Risk of injury
Risk of crushing due to the liquid container
tipping
Allow the lock to latch after tipping.
Behaviour in the event of an
emergency
DANGER
Risk of injury and material damage
when vacuuming inflammable materi-
als, or in the case of a short-circuit or
other electrical faults
Danger of inhalation of gases hazardous to
health, danger of electric shock, danger of
burns.
In the event of an emergency, switch off the
device and unplug the mains plug.
14
Electrical connection
The device may only be connected to an
electrical connection which has been set up
by a qualified electrician as per IEC 60364.
For the connection values see Technical
data and type plate. Use of an extension
cable is prohibited.
DANGER
Danger of electric shock
Danger of death
Avoid damaging the power cables by driv-
ing over them or otherwise crushing them,
or by jerking them.
Protect the cables from heat, oil and sharp
edges.
Check the mains connection of the device
for damage every time before operation.
Do not operate the device using a damaged
cable. Have any damaged cables replaced
by a qualified electrician.
Symbols on the device
Marking the maximum permissible fluid
level
See chapter Checking the filling level dis-
play.
ATTENTION
Risk of damage to the device
Leaking water due to the maximum fluid
level being exceeded.
Drain the device before the maximum fluid
level is reached.

Device description

See graphics page for illustrations
Illustration A
Accessory holder
1
Unlocking lever
2
Tilting chassis
3
Liquid container
4
Preliminary filter cover
5
Preliminary filter cover lock
6
Suction hose connection
7
Filter
8
Drum pump on/off switch
9
English

Werbung

Fehlerbehebung

loading

Diese Anleitung auch für:

Ivr-l 100/24-2Ivr-l 100/24-2 meIvr-l 100/24-2 tcIvr-l 100/24-2 tc meIvr-l 100/24-2 tc dpIvr-l 100/24-2 tc me dp ... Alle anzeigen