12. Troubleshooting

Fault
Possible cause
The compressor does
No supply voltage.
not start.
Insufficient supply voltage.
Outside temperature is too low.
Motor is overheated.
The compressor starts
The safety valve (17) leaks.
but there is no pres-
sure.
The seals are damaged.
The drain plug for condensation water (10)
leaks.
The compressor starts,
The hose connections have a leak.
pressure is shown on
the pressure gauge, but
A quick-lock coupling has a leak.
the tools do not start.
Insufficient pressure set on the pressure
regulator (5).
Remedy
Check the supply voltage, the power plug and the
socket-outlet.
Make sure that the extension cable is not too
long. Use an extension cable with large enough
wires.
Never operate with an outside temperature of
below +5° C.
Allow the motor to cool down. If necessary, rem-
edy the cause of the overheating.
Have a service center replace the safety valve
(17).
Check the seals and have any damaged seals
replaced by a service center.
Tighten the screw by hand. Check the seal on
the screw and replace if necessary.
Check the compressed air hose and tools and
replace if necessary.
Check the quick-lock coupling and replace if
necessary.
Increase the set pressure with the pressure
regulator.