ENGLISH
ADJUSTING THE BALANCE OF SQUEEGEE
1.
Install the squeegee and screw up the nut (16), then connect the vacuum hose (11) to the squeegee.
2.
Adjust the squeegee by squeegee adjusting handle (A, Figure 6).
a) If there is gap between the ground and middle section of rear squeegee blade (B), adjust the knob (A) in
counterclockwise direction (F) until all section of rear squeegee blade good contact with ground, the
front blade touch the ground slightly.
b) If there is gap between the ground and both end section of rear blade(C and D), adjust the knob (A) in
clockwise direction (E) until all section of rear blade good contact with the ground, the front blade touch
the ground slightly.
SOLUTION TANK FILLING
CAUTION!
Use only low-foam and non-flammable detergents that are intended for automatic scrubber
applications. When using the cleaning detergents, please follow the instructions on the labels of
detergent bottles and wear suitable gloves and protections to handle it.
Open the clean water inlet (26) to fill cleaning water or cleaning solvents to solution tank. Don't overfill the tank.
Stop filling when solution is centimeters near the edge.

REGULATING THE VOLUME OF WATER FLOW

WARNING!
The power switch (45) must on off position "o" before adjusting valve knob (A, Figure 7).
Adjust the valve knob to regulate the volume of the water flow basing on actual need. B in Figure 7 shows the
volume of the water flow.