Mounting and Connection Instructions IDENTLOC Glass Breakage Sensor
7.
Teaching mode
As every sensor has its own individual data code, the EU must be informed of this code in the
teaching mode.
This means that after each new installation of or alteration to the sensor, the codes of the
sensors have to be read in again in teaching mode by the EU.
An exact description of the teaching mode can be found in the mounting and connection
instructions on the evaluation unit, chapter "Teaching mode".
8.
Function check of the glass breakage sensor
On completion of the teaching mode,
checked in the display mode (operating state "disarmed cleared").
For this purpose, trigger the sensor with the sensor testing device (Item no. 032256.01).
The sensor is functioning correctly
- When the
LED
in the EU
Note:
A stored indication must be subsequently cleared.
9.
Final assembly
Installation is complete after a successful test run.
Cover the screw openings at the transmission units with the enclosed VdS seals!
10.
Technical data
Transmission distance between the housings
Side offset
Protection class as per DIN 40 050/EN 60 529
Environmental class as per VdS
Operating temperature range
Colour
VdS approval
Note!
The protection class IP 67 is only ensured when the
has been performed
The glass breakage sensor 032230.17 complies with the essential requirements of the
R&TTE 1999/5/EC Directive, if used for its intended use.
The EC-Declaration of Conformity can be downloaded from our homepage (Service / Download).
the function of the glass breakage sensor must be
flashes
and the triggering remains
correctly.
(see Chapter 6.5.3).
stored.
2 mm to 10 mm
5 mm max.
IP 67
III
-25 °C to +60 °C
Traffic white (similar to RAL 9016)
In combination with the transmission unit
Item no. 032220.17
protection against humidity
19