Herunterladen Diese Seite drucken

Atex Installation Drawings, Uk, Fr, De, Dk - 6334B - PR electronics 6334 Bedienungsanleitung

2-wire programable transmitter
Vorschau ausblenden Andere Handbücher für 6334:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ATEX Installation Drawings, UK, FR, DE, DK - 6334B

LERBAKKEN 10, 8410 RØNDE DENMARK.
Installation notes:
Downloaded from
www.Manualslib.com
ATEX Installation drawing
6331
For safe installation of 6331Bxx or 6334Bxx the following must be observed. The module shall only
be Installed by qualified personnel who are familiar with the national and international laws,
directives and standards that apply to this area.
Year of manufacture can be taken from the first two digits in the serial number.
ATEX Certificate
KEMA 06ATEX 0115
Marking
II 1 G Ex ia IIC T6..T5
Standards
EN 60079-0 : 2006, EN 60079-11 : 2007, EN 60079-26 : 2007
Hazardous area
Zone 0, 1, 2
T5: -40 ≤ Ta ≤ 60ºC
T6: -40 ≤ Ta ≤ 40ºC
Terminal:
41,42,43,44
Uo: 9.6 VDC
Io: 25 mA
Po: 60 mW
Lo: 33 mH
Co: 2.4 μF
Terminal:
51,52,53,54
Uo: 9.6 VDC
Io: 25 mA
Po: 60 mW
Lo: 33 mH
Co: 2.4 μF
The sensor circuit is not infallibly galvanically isolated from the input circuit. However, the
galvanic isolation between the circuits is capable of withstanding a test voltage of 500Vac
during 1 minute.
Revision date:
Version Revision
2009-09-29
manuals search engine
WWW.PRELECTRONICS.COM
44
+
43
13
-
42
11
41
CH1
Barrier
54
+
53
23
-
52
21
51
CH2
Barrier
6331 / 6334
V1R0
6334V105
6331QA01
Non Hazardous Area
Terminal:
11,13 and
21,23
Ui: 30 VDC
Ii: 120 mA
Pi: 0.84 W
Li: 10 μH
Ci: 1.0 nF
Page: