OPERATING THE APPLIANCE

Operation
Use high suction power if exces-
sive vapour is formed in kitchen. It
is recommended that furnace hood
suction unit is opened 5 minutes
before beginning cooking and is left
in operation during and for 15 min-
utes after cooking.
Control with levels
T1. Turning lights on/off (ON/OFF)
T2. Reducing speed
By pressing "T2" button, speed is re-
duced from level 4 (dense) to level 1.
By pressing "T2" button as hood
runs in level 1, hood is turned off
(switched to OFF position).
T3 Increasing speed
By pressing T3 button, hood switch-
es from OFF position to operation in
speed level 1.
By pressing the button (as hood is
ON position), the engine is ensured
to switch from level 1 to 4 (dense).
Each speed level has a correspond-
ing led light.
Speed level 1 led 1
Speed level 2 led 2
Speed level 3 led 3
Dense speed level led 4 (flashing)
Dense speed level is time adjusted.
Standard time adjustment is 5 min-
utes. At the end of that period, hood
switches to speed level 2.
18
Press T2 button to exit this mode
before period set, hood switches to
speed level 3.
T4 Time adjustment of speed
levels
Time adjustment of speed levels
are ensured by pressing T4 button,
when time set ends, hood is turned
off automatically.
Timing is below:
1. Speed level - 20 minutes (led 1
flashing)
Speed level 2 - 15 minutes (led 2
flashing)
Speed level 3 - 10 minutes (led 3
flashing)
Speed level 4 - 5 minutes (led 4
flashing)
If T2 button is pressed in timed op-
erating mode, hood leaves timed
operating mode and speed level is
decreased.
If T3 button is pressed, hood leaves
timed operating mode and speed
level is increased.
If T4 button is pressed, hood leaves
timed operating mode but speed
level is maintained without any
change.
Grease filter alarm
After 40 hours of operation, LED 1
starts blinking.
As this alarm emerges, it is time to
clean the grease filter.
In order to reset the alarm, press T4
button for 5 seconds.
A "BEEP" sound will be heard and
blinking of led 1 will end.