Installing/Mounting
2.2 Mounting the Transmitter
Wall Mounting
The transmitter can be mounted on any wall surface including wood, metal or concrete. Use
the appropriate bolts and screws as needed for your mounting application and adhere to
local codes.
● Recommended mounting: directly to wall or to electrical cabinet back panel.
● If alternate mounting surface is used it MUST support four times the weight of the unit.
Figure 2-1
Mounting the Enclosure
1. Loosen the Enclosure cover screws and open the cover to reveal the mounting screw
holes.
2. Mark and drill four holes in the mounting surface for the four #8 screws (supplied).
3. Fasten with a long flat-blade screwdriver.
8
Mounting holes
Enclosure cover screws
Wall Mounting
FST020 IP65 NEMA 4X Quick Start