CAT3Pro
When using arc welding equipment, always observe the provisions of EN 60974-4 Inspection
and testing, as well as any national laws and regulations.
Check the following:
Daily
10 Troubleshooting
#
DANGER
Risk of injury and device damage when handled by unauthorized persons
Improper repair work and modifications to the product may lead to serious injuries and
damage to the device. The product warranty will be rendered invalid if work is carried out on
the product by unauthorized persons.
• Only qualified personnel are permitted to perform work on the device or system.
Observe the attached "Warranty" document. In the event of any questions and/or problems,
please contact your retailer or the manufacturer.
NOTICE
• Consult the documentation for the welding components.
Fault
Torch mount
cannot be
attached.
CAT3Pro does
not activate the
stop signal.
BAL.0843.0 • 2020-11-03
-
Thoroughly remove dirt and weld spatter
from CAT3Pro.
-
Check that the helix cable functions
properly.
• Wrong torch mount is used.
• CAT3Pro mounting flange is
defective.
• Cable not connected between
the CAT3Pro and the cable
assembly.
• Helix cable is damaged.
• CAT3Pro switch is defective.
Monthly
Cause
10 Troubleshooting

Every six months

-
-
Troubleshooting
• Use the correct torch mount.
• Send the CAT3Pro for
repair.
• Connect the cable.
• Replace the helix cable.
• Send the CAT3Pro for
repair.