Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

O
M
 
PERATING 
ANUAL

Home screen

Ready indicator:  This square icon indicates whether the machine is at temperature to dispense. When 
first starting the machine, the indicator will remain red in color until all temperature zones are heated to 
set temperature. Once all zones are at temperature, the icon will turn green, indicating that we are now 
ready to dispense. 
Temperature set value:  This is the current set‐point value in degrees for the active heat zone. The 
temperature shown here is only for reference. To change the temperature set value, refer to the section 
of this manual labelled 
Steps to creating a new pour‐over profile.
Heat zone:   In automatic temperature mode, this button has no function. In manual temperature mode, 
pressing this button cycles through the 2 heat zones on the pour‐over system: Inlet Boiler and Outlet 
Boiler. 
(Refer to Advanced preferences screen page 2)
Settings button:  This button navigates to the main settings screen. 
Machine name & status:  Displays the current name and status of the module & tap. 
Pour‐over profile button assignments:  Displays which pour‐over program (profile) is selected for each 
of the dispensing switches (L = Left switch, R = Right switch). 
Time read‐out:  Displays the current time from the start of the dispensing readout. 
Volume read‐out:  Displays real‐time fluid volume information during a dispensing cycle. 
 
 
 
 
 
 
 
P
OUR 
O
S
 
VER 
YSTEM
 
10 

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für modbar POUR OVER SYSTEM

Inhaltsverzeichnis