4. REFRIGERANT FLOW DIAGRAM

4-1. Refrigerant Flow Diagram
Outdoor Unit
Indoor unit
Insulation of Refrigerant Tubing
IMPORTANT
Because capillary tubing is used in the outdoor unit, both the
wide and narrow tubes of this air conditioner become cold. To
prevent heat loss and wet floors due to dripping of
condensation, both tubes must be well insulated with a
proper insulation material. The thickness of the insulation
should be a min. 8 mm.
CAUTION
Downloaded from
www.Manualslib.com
CU-5E34NBE
Service valve on
wide tube
Wide tube
EW
O.D.12.7mm
DW
O.D.12.7mm
CW
O.D.9.52mm
BW
O.D.9.52mm
AW
O.D.9.52mm
Service valve on
narrow tube
EN
Narrow tube
O.D.6.35mm
DN
O.D.6.35mm
CN
O.D.6.35mm
BN
O.D.6.35mm
AN
O.D.6.35mm
After a tube has been insulated,
never try to bend it into a narrow
curve because it can cause the tube
to break or crack.
manuals search engine
Outdoor unit
Sub
accumulator
Header
4-way
valve
Electric
Defrost valve
expansion
for hot gas bypass
valve
M
M
M
M
M
Strainer
Header
Thickness:
Min. 8 mm
10
Main
accumulator
Muffler
S
Receiver tank
Insulation
Narrow tube
Wide tube
Cooling cycle
Heating cycle
Defrosting cycle
Thickness:
Min. 8 mm