8-2-2. Display of the Error Monitor Lamps
ERROR MONITOR LAMP
ERR0
ERR1
Downloaded from
www.Manualslib.com
ERR2
ERR3
DIAGNOSTICS ITEM
SENSOR FOR BRANCH PIPE A
FAILURE (NARROW TUBE)
SENSOR FOR BRANCH PIPE B
FAILURE (NARROW TUBE)
SENSOR FOR BRANCH PIPE C
FAILURE (NARROW TUBE)
SENSOR FOR BRANCH PIPE D
FAILURE (NARROW TUBE)
SENSOR FOR BRANCH PIPE E
FAILURE (NARROW TUBE)
SENSOR FOR BRANCH PIPE A
FAILURE (WIDE TUBE)
SENSOR FOR BRANCH PIPE B
FAILURE (WIDE TUBE)
SENSOR FOR BRANCH PIPE C
FAILURE (WIDE TUBE)
SENSOR FOR BRANCH PIPE D
FAILURE (WIDE TUBE)
SENSOR FOR BRANCH PIPE E
FAILURE (WIDE TUBE)
SENSOR FOR COMPRESSOR
DISCHARGE TEMP FAILURE
SENSOR FOR HEAT EXCHANGER
TEMP FAILURE
SENSOR FOR OUTDOOR AIR TEMP
FAILURE
HIC CIRCUIT TROUBLE
ACTUATION OF FREEZE
PROTECTION FUNCTION
ACTUATION OF COMPRESSOR
OVER LOAD RELAY
ELECTRICAL CURRENT SENSOR
FAILURE
EXTERNAL ROM (OTP DATA)
FAILURE
PEAK CURRENT CUT-OFF
PAM (PFC) CIRCUIT FAILURE
COMPRESSOR DISCHARGE
OVERHEAT PREVENTION ACTIVATED
DC COMPRESSOR DRIVE FAILURE
NO-REFRIGERANT PROTECTION
DC FAN MOTOR DRIVE FAILURE
manuals search engine
.... OFF
....
Blinking
DIAGNOSTICS CONTENTS
(1) SENSOR OPEN CIRCUIT OR SHORT CIRCUIT
(2) CONTACT FAILURE AT CONNECTOR OR OPEN CIRCUIT AT TERMINAL
CRIMPING LOCATION
(1) HIC OR POWER TR FAILURE (2) OUTDOOR FAN DOES NOT TURN
(3) INSTANTANEOUS POWER OUTAGE (4) SERVICE VALVE NOT OPENED
(5) OUTDOOR FAN FAILURE (6) CONTINUOUS OVER LOAD OPERATION
(7) COMPRESSOR FAILURE (8) HIC BOARD FAILURE
(1) SENSOR FAILURE (2) FAILURE OF ELECTRONIC EXPANSION VALVE
(3) IMPROPER TUBING CONNECTION (4) CONTROL P.C.BOARD FAILURE
(1) VALVE CLOSURE (2) FAILURE OF ELECTRONIC EXPANSION VALVE
(3) OLR LEAD WIRE BREAKING (4) CONTROL P.C.BOARD FAILURE
(1) CONTROL P.C.BOARD OR NOISE FILTER P.C.BOARD FAILURE
(1) EXTERNAL ROM DATA FAILURE (2) CONTROL P.C.BOARD FAILURE
(1) OPERATING CURRENT IS 23A OR HIGHER
(1) PAM CIRCUIT ABNORMAL VOLTAGE
(2) PROTECTION FOR CURRENT (3) HIC BOARD FAILURE
(1) ELECTRONIC EXPANSION VALVE FAILURE (2) CAPILLARIES CHOKED
(3) SHORTAGE OF REFRIGERANT
(1) OPEN PHASE (2) COMPRESSOR FAILURE
(3) CONTROL P.C.BOARD OR HIC BOARD FAILURE
(1) SERVICE VALVE NOT OPENED (2) SHORTAGE OF REFRIGERANT
(1) CONTACT FAILURE AT CONNECTOR (2) FAN MOTOR FAILURE
(3) CONTROL P.C.BOARD FAILURE
28
....
Illuminated
852-6-4423-567-00-1