5.3.5
%I prewarning and limitation
5.3.5.1
%I prewarning
%I limitation
5.3.5.2
The "%I prewarning" parameter can be used to specify
• from which scale value on the message "Phase angle prewarning re
ached" is to be displayed.
The timer is thus able, in the KSR mode, to call your attention to an im
minent %I limitation resulting e.g. from cable losses in the secondary
circuit.
Parameter setting in BOS:
In "Programming", flag "Electrode", parameter group "Limitation"
The parameter value must be lower than the value for the %I limita
tion.
"
Parametrize the %I prewarning first.
The parameter value must be higher than the value for the %I
prewarning.
Using the "%I limitation" parameter, you define the maximum permitted
scale value. It limits
• the scale value specified by the controller to the power supply unit in
KSR mode, and
• the possible programming input in PHA mode.
If the %I limitation is activated, the timer will output the message "Maxi
mum phase angle".
Parameter setting in BOS:
In "Programming", flag "Electrode", parameter group "Limitation".
The input value for %I limitation is effective absolutely!
The function "%I correction" (refer to page 292) and "%I stepping"
(refer to page 285) can therefore lead to the activation of the %I limit
ation.
PST 6xxEx |