286 / 416
Bosch Rexroth AG
Information on this product
5.3.10.4
Warning and Maximum electrode life
5.3.10.5
Prewarning table
When the maximum tolerable wear has been reached, new electrodes
have to be installed.
In this context, the following output signals are available
• "Warning cap change"
• "Maximum cap life" or
• "Request cap change"
These are only used when the electrode maintenance function is active
(parameter "Stepping": ON).
Parameter setting in BOS:
In "Programming", flag "Stepping", parameters "Warning wear" and
"Max. wear".
For electrodes with active electrode maintenance function, the prewar
ning table provides an overview giving quick access to all important in
formation and operations:
• weld timers allocated to the individual electrodes,
• current wear (percentage, numerical and graphical).
The graphic display is color‐coded. Existing prewarnings, tip‐dress
requests or the reaching of maximum electrode life can thus be reco
gnized quickly.
• remaining parts which can still be produced with the respective elec
trode,
• resetting of one or several wear counters after cap change.
PST 6xxEx |
1070087088 / 08