R911381739 | PRC 7x00-Lx/Wx-402
Bosch Rexroth AG | Electric Drives and Controls
6.3
Serial SERCOS IO input/output array with 24 discrete
inputs and outputs and 2 analog input and 2 analog
output (HIP module 1)
Tab. 24: SERCOS IO 32 discrete inputs
Bits
Inputs:
DI_00
Not used
DI_01
Not used
DI_02
Not used
DI_03
Not used
DI_04
Not used
DI_05
Not used
DI_06
Pressure monitor air
DI_07
Not used
DI_08
Pressure monitor water
DI_09
Not used
DI_10
Not used
DI_11
Not used
DI_12
Not used
DI_13
Not used
DI_14
Not used
DI_15..23
Not used
Tab. 25: SERCOS IO with 32 discrete outputs
Bits
Outputs:
DO_00
Ready
DO_01
Timer fault
DO_02
Welding fault
DO_03
Gun ready for welding
DO_04
Water stop valve on
DO_05
Not used
DO_06
Not used
DO_07
Not used
DO_08
Display 1_1
DO_09
Display 1_2
DO_10
Display 1_3
DO_11
Display 1_4
DO_12
Not used
DO_13
Not used
DO_14
Not used
35/46