Display text
|Battery error|
|Maintenance date|
ing)
|Undercurrent 1
2|
or
|Overcurrent 1
2|
or
|Relay error 1
2|
or
|Power outage|
|Temperature error 1a
2a|
|Temperature error 1b
or 2b|
|Level error|
|Phase failure|
|Rotating field error|
|Motor protection 1 or
2|

|Pressure loss|

|Relay operating
cycles|
|Max. run time 1
or
2
1
010-532
PFC
Possible cause
2
E
Battery is missing, is faulty or volt-
age less than 13.5V.
(flash-
-
Maintenance date is reached.
No maintenance date entered.
-
Minimum power consumption of
the pump not reached.
Control unit-pump cable inter-
rupted.
Pump is defective.
-
Maximum power consumption of the
pump exceeded, possible impeller
blockage.
E
Power contactor does not switch off.
-
Power supply has failed.
Miniature fuse of the unit (S1) has
tripped.
Power supply has failed, circuit
breaker has tripped.
Main switch is defective - mains
supply cable interrupted.
or
E
Self-resetting temperature monitor-
ing has tripped.
E
NON self-resetting temperature
monitoring has tripped.
E
Incorrect layout or wiring of the
probes
The sensors in the control unit are
configured incorrectly,
-
Phase L2 or L3 is no longer applied.
E
Incorrect rotating field of the mains
connection.
E
Motor protection switch has tripped
- motor protection switch set incor-
rectly.
Pumping current too high due to
faulty or blocked pump.
Excessive current due to phase fail-
ure.
E
Hose at the fitting to the immer-
sion pipe (or submersible pressure
switch) or control unit is leaking.
E
Maximum operating cycles
exceeded.
2|
E
Pump runs too long per pumping
operation.
Installation and operating manual
Remedial measure
Check battery charge state, correct
connection and damage to the battery
connection terminals.
Carry out maintenance.
Enter maintenance date.
none - general power outage.
Check fuse.
Check main switch.
Check mains cable. Deliberate
switching off, shut down con-
trol unit (see "Switch on and off",
page 36).
Self-resetting - the pump starts again
automatically when the motor has
cooled down. The error message is
acknowledged automatically. Replace
the pump if the temperature error
occurs frequently.
NON self-resetting - the pump
remains inactive, even after the motor
has cooled down. It is necessary to
switch off and switch on again the
control unit. Replace the pump if the
temperature error occurs frequently.
Functional check as described in the
system documentation.
Check power supply cable and fuses.
Swap 2 phases of power cable.
Set current value according to
pump.
Remove blockage.
Replace pump, if defective. Check
mains for phase failure.
Check tightness of the pressure sen-
sor system.
Can be acknowledged. Inform cus-
tomer service. Error appears after a
further 1000 operating cycles.
Check the system design, if neces-
sary, inform the customer service.
39 / 136