Dispose of the fleece filter bag accord-
ing to the local provisions.
Insert the new fleece filter bag.
Insert and lock the suction head.
Replace the disposal bag
Illustration
Release and remove the suction head.
Put the disposal bag (option) over.
Tightly close the disposal bag (option)
with cable tie underneath the opening.
Remove disposal bag (option).
Dispose of the dust bag (special acces-
sory) in accordance with statutory provi-
sions.
Insert the new disposal bag (option).
Pull disposal bag (option) over the con-
tainer.
Make sure that the marking line is situ-
ated within the container and both ven-
tilation holes are positioned at the back
of the container.
Insert and lock the suction head.
Cleaning the electrodes
Release and remove the suction head.
Clean the electrodes with a brush.
Insert and lock the suction head.
Troubleshooting
DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Note: In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
Suction turbine does not run
Check the receptacle and the fuse of
the power supply.
Check the power cable, the power plug
and electrodes of the device.
Turn on the appliance.
Suction turbine turns off
Empty the container.
Suction turbine does not start again
after the container has been
Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
Clean the electrodes with a brush.
Suction capacity decreases
Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
Replacing the full fleece filter bag.
Replace the filled disposal bag (option).
Press the semi-automatic filter dedust-
ing key five times with the appliance
switched on.
Ensure the filter cover properly locks
into place.
Replace the flat pleated filter.
Dust comes out while vacuuming
Illustration
Check/correct the correct positioning of
the flat pleated filter.
Replace the flat pleated filter.
Automatic shut-off (wet vacuum
cleaning) does not react
Clean the electrodes with a brush.
Continuously check the filling level in
case of non-conductive liquid.
Semi-automatic filter dedusting
Suction hose is not connected.
Semi-automatic filter dedusting
does not shut off
Inform Customer Service.
Semi-automatic filter dedusting
cannot be switched on
Inform Customer Service.
– 6
EN
emptied
does not work
19