Turn off the appliance
 Press the semi-automatic filter dedust-
ing key five times.
 Switch off the appliance at the main
switch.
 Pull out the mains plug.
After each operation
 Empty the container.
 Vacuum and wipe the appliance inside
and outside with a damp cloth.
Storing the Appliance
Illustration
 Store the suction hose and the mains
cable as shown in the illustration.
 Place the appliance in a dry room and
secure it from unauthorized use.

Transport

CAUTION
Risk of injury and damage! Observe the
weight of the appliance when you transport it.
 Remove the suction pipe with the floor
nozzle from the holder. Hold the appli-
ance at the handle and at the suction
pipe to transport it.
 When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
CAUTION
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.

Care and maintenance

DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Exchanging the flat pleated filter
 Open filter door.
 Replace the flat pleated filter.
 Close the filter door, it must lock into
place.
16

Storage

Cleaning the electrodes
 Release and remove the suction head.
 Clean the electrodes with a brush.
 Insert and lock the suction head.

Troubleshooting

DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Suction turbine does not run
 Check the receptacle and the fuse of
the power supply.
 Check the power cable, the power plug,
the electrodes and possibly the recep-
tacle of the device.
 Turn on the appliance.
Suction turbine turns off
 Empty the container.
Suction turbine does not start again
after the container has been
 Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
 Clean the electrodes as well as the
space between the electrodes with a
brush.
Suction capacity decreases
 Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
 Replace fleece filter bag.
 Press the semi-automatic filter dedust-
ing key five times with the appliance
switched on.
 Ensure the filter cover properly locks
into place.
 Clean or replace the membrane filter
(special accessory) under running wa-
ter.
 Replace the flat pleated filter.