Herunterladen Inhalt Inhalt Diese Seite drucken

Uninstalling The Heat Pump; Cleaning - Steinbach Waterpower 5000 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Waterpower 5000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
- Pay attention to maintaining proper posture (straight back,
secure footing, etc.).
- Use transport aids (e.g. pallet truck, or creeper dolly).
- Wear protective equipment such as safety footwear or gloves.

Uninstalling the heat pump

Uninstalling the heat pump from its setup location
1. Loosen the fasteners between the feet and the ground anchors.
2. Lift the heat pump off the ground anchors.
The heat pump is uninstalled from its setup location.

Cleaning

Improper cleaning can result in damage to the device.
- Clean the surface of the device with clear water after every use.
- Do not use any aggressive cleaning agents.
- Do not use any sharp or metallic objects such as knives, hard
putty knives or the like.
- Do not use any cleaning brushes.
- Do not use a high-pressure cleaner.
Cleaning the heat pump
1. Clean the housing and the grill of the fan
2. Carefully clean the fins of the finned heat exchanger
3. Remove deposits from the drain connection piece
can drain away freely.
4. Dry the heat pump with a dry cloth.
The heat pump is cleaned.
64
NOTE!
with a damp cloth.
10
11
so that the condensation water
5
with a dry cloth.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis