Problem
Logs are not being split properly
(insufficient splitting performance)
Log ram travels out jerkily or under heavy
vibration
Log ram will not move out
Motor will not start
Oil leak at the dipstick
Splitting force
Log length
Log diameter
Stroke
Piston rod diameter
Hydraulic oil (max.)
Electric motor performance (power consumption)
Power supply
Revolutions
Dimensions
Weight
Downloaded from
www.Manualslib.com
P
P
possible cause
⇒ The log is not positioned correctly
⇒ The log exceeds the maximum
dimensions or the wood is too hard for
the performance of the machine
⇒ The splitting wedge is not working
properly
⇒ Oil leak
⇒ Hydraulic pressure too low
⇒ Incorrect connecting lead (longer than
10 m or too small cable cross-section)
⇒ Air in the circuit
⇒ Hydraulic pump defective
⇒ No electrical power
⇒ Connection cable defective
⇒ Electric motor defective
⇒ Oil seal at the dipstick not sealing
manuals search engine
o
s
s
i
b
l
e
p
r
o
b
l
e
m
s
o
s
s
i
b
l
e
p
r
o
b
l
e
m
s
T
e
c
h
n
i
c
a
l
d
a
t
a
T
e
c
h
n
i
c
a
l
d
a
t
a
15
remedy
⇒ Reposition the log correctly
⇒ Cut the log to the required dimensions
⇒ Sharpen the splitting wedge, and check
for any burrs or notches
⇒ Place a sheet of cardboard under the
log splitter in order to locate the leak.
To correct the problem, refer to the
manufacturer
or
other
service centre.
⇒ Check the oil level and add more oil if
necessary.
If the problem cannot be rectified, refer
to the manufacturer or other approved
service centre.
⇒ Use the correct connecting lead
⇒ Open the bleed screw
⇒ Check the oil level and add more oil if
necessary.
If the problem cannot be rectified, refer
to the manufacturer or other approved
service centre.
⇒ To correct the problem, refer to the
manufacturer
or
other
service centre.
⇒ Check the fuse (16 A).
⇒ Replace the connection cable or have
it checked by an electrician.
⇒ To correct the problem, refer to the
manufacturer
or
other
service centre.
⇒ Replace the oil seal.
50 – 250 mm
P
= 1500 W ( S1-100 % )
1
230 V ~ 50 Hz
Length 1115 x Width 320 x Height 470 mm
approved
approved
approved
40 kN (4 t)
370 mm
300 mm
30 mm
2.6 litres
2850 rpm
45 kg