Herunterladen Inhalt Inhalt Diese Seite drucken

Parker PACHC Serie Bedienungsanleitung Seite 50

Elektrohydraulische reglerbaugruppe
Inhaltsverzeichnis

Werbung

Elektrohydraulische Reglerbaugruppe
Serie PACHC
Index
Group
Plain Text
Variablename
model-
based-
u32_MbffWDataGridRec-
axis0_u32_MbffWDataG-
560F
0
feedfor-
TargetAcceleration
ridRecTargetAcceleration
ward0
model-
based-
u32_MbffWDataGridRec-
axis0_u32_MbffWDataG-
5610
0
feedfor-
TargetDeceleration
ridRecTargetDeceleration
ward0
model-
based-
u32_MbffWDataGridRec-
axis0_u32_MbffWDataG-
5611
0
feedfor-
TargetJerk
ridRecTargetJerk
ward0
model-
based-
u32_MbffWDataGridRec-
axis0_u32_MbffWDataG-
5612
0
feedfor-
TargetJerkDecel
ridRecTargetJerkDecel
ward0
model-
based-
axis0_i16_MbffwSystem-
5613
0
i16_MbffwSystemChoice
feedfor-
Choice
ward0
model-
based-
f_MbffwVelocityChange-
axis0_f_MbffwVelocity-
5614
0
feedfor-
Phases
ChangePhases
ward0
model-
based-
5615
0
f_MbffwDampingCyl
axis0_f_MbffwDampingCyl FLOAT
feedfor-
ward0
model-
based-
axis0_f_MbffwResFre-
5616
0
f_MbffwResFrequCyl
feedfor-
quCyl
ward0
model-
based-
axis0_f_MbffwResFre-
5617
0
f_MbffwResFrequValve
feedfor-
quValve
ward0
analog
AOut_u8_OutputFunc-
5850
0
Output functions 1
output
tions1
valve
AOut0_u8_ValveIn-
5A50
0
Valve input source 0
config 0
putSource
valve
5A51
0
Valve type 0
AOut0_u8_ValveType
config 0
valve
AOut0_u8_ValveSignal-
5A52
0
Valve signal type 0
config 0
Type
valve
Valve actuation range po-
AOut0_u8_ValveActuation-
5A53
0
config 0
sition controller 0
RangePosCtrl
Valve actuation ran-
valve
AOut0_u8_ValveActuation-
5A54
0
ge pressure/force cont-
config 0
RangeFCtrl
roller 0
valve
5A55
0
Valve open loop 0
AOut0_u8_ValveOpenLoop UNSIGNED8
config 0
valve
Valve open loop set-
AOut0_f_ValveOpenLoop-
5A56
0
config 0
point 0
Setpoint
output
Output chain input sour-
AOut0_u8_CtrlOutChainIn-
5A80
0
chain0
ce 0
putSource
Position controller direc-
output
AOut0_f_CtrlOutPosCtrl-
5A81
0
tion dependent gain fac-
chain0
DirDepGainFactorPos
tor positive 0
Position controller direc-
output
AOut0_f_CtrlOutPosCtrl-
5A82
0
tion dependent gain fac-
chain0
DirDepGainFactorNeg
tor negative 0
Pressure controller direc-
output
AOut0_f_CtrlOutFCtrlDir-
5A83
0
tion dependent gain fac-
chain0
DepGainFactorPos
tor positive 0
98
Anhang
Auflö-
Werte-
Save to
Datentyp
Zugriffsrechte
Einheit
sung
bereich
flash
mm/
UNSIGNED32 READWRITE
1
No
s^2
mm/
UNSIGNED32 READWRITE
1
No
s^2
mm/
UNSIGNED32 READWRITE
1
No
s^3
mm/
UNSIGNED32 READWRITE
1
No
s^3
INTEGER16
READWRITE
No
FLOAT
READWRITE
0.1
mm/s
No
READWRITE
No
FLOAT
READWRITE
0.001
1/s
No
FLOAT
READWRITE
0.001
1/s
No
UNSIGNED8
READWRITE
Yes
UNSIGNED8
READWRITE
Yes
UNSIGNED8
READWRITE
0..2
Yes
UNSIGNED8
READWRITE
0..3
No
UNSIGNED8
READWRITE
0..3
Yes
UNSIGNED8
READWRITE
0..3
Yes
READWRITE
0..1
No
FLOAT
READWRITE
%
No
UNSIGNED8
READWRITE
Yes
FLOAT
READWRITE
Yes
FLOAT
READWRITE
Yes
FLOAT
READWRITE
Yes
PACHC 5715-720DE.indd 09.06.20
Elektrohydraulische Reglerbaugruppe
Serie PACHC
Index
Group
Plain Text
Variablename
Pressure controller direc-
output
AOut0_f_CtrlOutFCtrlDir-
5A84
0
tion dependent gain fac-
chain0
DepGainFactorNeg
tor negative 0
output
Controller output inver-
AOut0_i8_CtrlOutInver-
5A85
0
chain0
ting sign 0
tingSign
Controller output dead
output
AOut0_i8_CtrlOutDBCom-
5A86
0
band compensation
chain0
pType
type 0
Controller output dead
output
AOut0_f_CtrlOutDBComp-
5A87
0
band compensation
chain0
Threshold
threshold 0
Controller output dead
output
AOut0_f_CtrlOutDBCom-
5A88
0
band compensation A
chain0
pASide
side 0
Controller output dead
output
AOut0_f_CtrlOutDB-
5A89
0
band compensation B
chain0
CompBSide
side 0
output
Controller output zero
AOut0_f_CtrlOutZeroCor-
5A8A 0
chain0
correction offset 0
rectionOffset
output
Default value inactive
AOut0_f_CtrlOutInacti-
5A8B 0
chain0
chain 0
veChain
output
Controller output lower li-
AOut0_f_CtrlOutLower-
5AAA 0
chain0
mit 0
Limit
output
Controller output upper li-
AOut0_f_CtrlOutUpper-
5AAB 0
chain0
mit 0
Limit
output
5AB0 0
Linearisation out 0
AOut0_f_LinOut
chain0
valve
AOut1_u8_ValveIn-
5B50
0
Valve input source 1
config 1
putSource
valve
5B51
0
Valve type 1
AOut1_u8_ValveType
config 1
valve
AOut1_u8_ValveSignal-
5B52
0
Valve signal type 1
config 1
Type
valve
Valve actuation range po-
AOut1_u8_ValveActuation-
5B53
0
config 1
sition controller 1
RangePosCtrl
Valve actuation ran-
valve
AOut1_u8_ValveActuation-
5B54
0
ge pressure/force cont-
config 1
RangeFCtrl
roller 1
valve
5B55
0
Valve open loop 1
AOut1_u8_ValveOpenLoop UNSIGNED8
config 1
valve
Valve open loop set-
AOut1_f_ValveOpenLoop-
5B56
0
config 1
point 1
Setpoint
output
Output chain input sour-
AOut1_u8_CtrlOutChainIn-
5B80
0
chain1
ce 1
putSource
Position controller direc-
output
AOut1_f_CtrlOutPosCtrl-
5B81
0
tion dependent gain fac-
chain1
DirDepGainFactorPos
tor positive 1
Position controller direc-
output
AOut1_f_CtrlOutPosCtrl-
5B82
0
tion dependent gain fac-
chain1
DirDepGainFactorNeg
tor negative 1
Pressure controller direc-
output
AOut1_f_CtrlOutFCtrlDir-
5B83
0
tion dependent gain fac-
chain1
DepGainFactorPos
tor positive 1
Pressure controller direc-
output
AOut1_f_CtrlOutFCtrlDir-
5B84
0
tion dependent gain fac-
chain1
DepGainFactorNeg
tor negative 1
output
Controller output inver-
AOut1_i8_CtrlOutInver-
5B85
0
chain1
ting sign 1
tingSign
Controller output dead
output
AOut1_i8_CtrlOutDBCom-
5B86
0
band compensation
chain1
pType
type 1
Controller output dead
output
AOut1_f_CtrlOutDBComp-
5B87
0
band compensation
chain1
Threshold
threshold 1
PACHC 5715-720DE.indd 09.06.20
Anhang
Auflö-
Werte-
Save to
Datentyp
Zugriffsrechte
Einheit
sung
bereich
flash
FLOAT
READWRITE
Yes
INTEGER8
READWRITE
0..1
Yes
INTEGER8
READWRITE
0..2
Yes
-1000..
FLOAT
READWRITE
0.1
%
Yes
1000
-1000..
FLOAT
READWRITE
0.1
%
Yes
1000
-1000..
FLOAT
READWRITE
0.1
%
Yes
1000
-1000..
FLOAT
READWRITE
0.1
%
Yes
1000
-1000..
FLOAT
READWRITE
0.1
%
Yes
1000
-1000..
FLOAT
READWRITE
0.1
%
Yes
1000
-1000..
FLOAT
READWRITE
0.1
%
Yes
1000
-1000.
FLOAT
READWRITE
0.1
%
No
1000
UNSIGNED8
READWRITE
Yes
UNSIGNED8
READWRITE
0..2
Yes
UNSIGNED8
READWRITE
0..3
Yes
UNSIGNED8
READWRITE
0..3
Yes
UNSIGNED8
READWRITE
0..3
Yes
READWRITE
0..1
No
FLOAT
READWRITE
%
no
UNSIGNED8
READWRITE
Yes
FLOAT
READWRITE
Yes
FLOAT
READWRITE
Yes
FLOAT
READWRITE
Yes
FLOAT
READWRITE
Yes
INTEGER8
READWRITE
0..1
Yes
INTEGER8
READWRITE
0..2
Yes
-1000..
FLOAT
READWRITE
0.1
%
Yes
1000
99

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis