8.1.5
Oscilloscope measurement functions
Measurement
Measuring range
functions
Secondary voltage 5 kV – 50 kV
Primary voltage
20 V – 500 V
Voltage
200 mV – 200 V
5 V – 500 V
AC coupling
200 mV – 5 V
Power
2 A
5 A
10 A
20 A
30 A
Power
50 A
100 A
200 A
1000 A
The measuring range is positive or negative depending on the
1)
base line.
The measuring range is greater than the permissible measure-
2)
ment voltage
8.1.6
Oscilloscope functions and specifications
Function
Input coupling CH1/CH2
Input impedance CH1/CH2
(relative to ground)
Input impedance CH1/CH2
(galvanically insulated)
Input impedance CH2
(switchover)
Bandwidth CH1
(galvanically insulated)
Bandwidth CH1 (relative to
ground)
Bandwidth CH2 (relative to
ground)
Bandwidth
measurement cable with volt‑
age divider
Bandwidth CH2
(differential measurement)
Bandwidth 1000 A amps clamp
Bandwidth 30 A amps clamp
Bandwidth secondary
measuring sensor
Bandwidth
Primary connecting cable (UNI 4)
Time ranges (relative to 500
scanning points)
Time ranges (relative to
1 scanning point)
Time base accuracy
Vertical accuracy
Device without sensors
Vertical resolution
Robert Bosch GmbH
Sensors
1)
Secondary
2)
Measuring sensor
Primary connecting ca‑
2)
ble (UNI 4)
CH1/CH2 Multi mea‑
2)
surement cable
Measurement cable
2)
with voltage divider
Connecting cable B+/B–
Amps clamp 30 A
Amps clamp 1000 A
Specification
AC/DC
1 MOhm
1 MOhm (5 – 200 V)
10 MOhm (200 mV — 2 V)
4 MOhm
> 5 kHz = 200 mV – 2 V
> 25 kHz = 5 V – 200 V
> 1 MHz = 200 mV – 2 V
> 5 MHz = 5 V – 200 V
> 1 MHz = 200 mV – 2 V
> 5 MHz = 5 V – 200 V
> 500 kHz
> 30 kHZ
> 1 kHz
> 50 kHz
> 1 MHz
> 100 kHz (20 V)
> 1 MHz (50 V – 500 V)
10 µs – 100 s
20 ns – 200 ms
0.01%
±2% of measured value
±0.3% of measuring range
(Offset error for ranges > 1 V)
or ±5 mV (offset error for
ranges 200 mV – 1 V)
10 bit
Technical Data | FSA 740 Edition | 31
Function
Memory depth
Scan rate per channel
8.2

Signal generator

Function
Specification
Amplitude
‑10 V – 12 V
(load < 10 mA) to ground
Signal forms
DC, sinusoidal, triangular, square‑
wave
Frequency range
1 Hz – 1 kHz
Output current
30 mA – 75 mA
(load‑dependent)
Impedance
approx. 60 Ohm
Symmetry
10% – 90%
(triangle, square)
Curve generation
Output rate up to 100000 values/s,
Resolution 8 bit, Y‑full range adjust‑
able ( bit), Unipolar/bipolar mode
Short‑circuit resistance
< 50 V static
to interference voltage
Short‑circuit resistance
< 500 V/1 ms dynamic
to interference voltage
R
Automatically activated filters and attenuators for
enhanced signal quality.
R
Automatic shut‑off in the case of short circuit,
detection of interference voltage on starting signal
generator.
8.3
Power supply unit
Function
Input voltage
Input frequency
Output voltage
Operating Temperature
8.4
Noise emissions
< 70 dB(A)
8.5
Dimensions and weights
Function
Dimensions H x W x D:
Weight
8.6
Temperature and humidity
Designation
Operating temperature
Storage temperature
Relative humidity in operation
en
Specification
1 Mega scan values or 50
curves
50 Ms/s
Specification
90 VAC – 264 VAC
47 Hz – 63 Hz
15 V
0 °C – 40 °C
Specification
1785 x 680 x 670 mm
91 kg
Value/Range
5 °C – 40 °C
41 °F – 104 °F
‑25 °C – 60 °C
‑13 °F – 140 °F
90 % non‑condensing
1 689 989 297
|
2016-05-05

Werbung