8.1.5
Oscilloscope measurement functions
Measurement
Measuring range
functions
Secondary voltage 5 kV – 50 kV
Primary voltage
20 V – 500 V
Voltage
200 mV – 200 V
5 V – 500 V
AC coupling
200 mV – 5V
Power
2 A, 5 A, 10 A,
20 A, 30 A
Power
50 A, 100 A,200 A
1000 A
The measuring range is positive or negative depending on the base line.
1)
The measuring range is greater than the permissible measure-
2)
ment voltage
8.1.6

Oscilloscope functions and specifications

Function
Input coupling CH1/CH2
Input impedance CH1/CH2
(relative to ground)
Input impedance CH1/CH2
(galvanically insulated)
Input impedance CH2
(switchover)
Bandwidth CH1
(galvanically insulated)
Bandwidth CH1 (relative to
ground)
Bandwidth CH2 (relative to
ground)
Bandwidth measurement cable
with voltage divider
Bandwidth CH2
(differential measurement)
Bandwidth 1000 A Amps clamp
Bandwidth 30 A Amps clamp
Bandwidth secondary
measuring sensor
Bandwidth
Primary connecting cable (UNI 4)
Time ranges (relative to 500 scan‑
ning points)
Time ranges (relative to
1 scanning point)
Time base accuracy
Vertical accuracy
Device without sensors
Vertical resolution
Memory depth
Scan rate per channel
Robert Bosch GmbH
Sensors
1)
Secondary
2)
measuring sensor
Primary connecting ca‑
2)
ble (UNI 4)
CH1/CH2
2)
Multi measurement ca‑
ble
2)
Measurement cable
with
voltage divider
Connecting cable
B+/B–
Amps clamp 30 A
Amps clamp 1000 A
Specification
AC/DC
1 MOhm
1 MOhm (5 – 200 V)
10 MOhm (200 mV — 2 V)
4 MOhm
> 5 kHz = 200 mV – 2 V
> 25 kHz = 5 V – 200 V
> 1 MHz = 200 mV – 2 V
> 5 MHz = 5 V – 200 V
> 1 MHz = 200 mV – 2 V
> 5 MHz = 5 V – 200 V
> 500 kHz
> 30 kHZ
> 1 kHz
> 50 kHz
> 1 MHz
> 100 kHz (20 V)
> 1 MHz (50 V – 500 V)
10 µs – 100 s
20 ns – 200 ms
0.01%
±2% of measured value
±0.3% of measuring range
(Offset error for ranges >
1 V) or ±5 mV(offset error
for ranges 200 mV – 1 V)
10 bit
1 Mega scan values or 50
curves
50 Ms/s
Technical Data | FSA 740 Edition | 31
8.2

Signal generator

Function
Specification
Amplitude
‑10 V – 12 V
(load < 10 mA) to ground
Signal forms
DC, sinusoidal, triangular, square‑
wave
Frequency range
1 Hz – 1 kHz
Output current
30 mA – 75 mA
(load‑dependent)
Impedance
approx. 60 Ohm
Symmetry
10% – 90%
(triangle, square)
Curve generation
Output rate up to 100000 values/s,
Resolution 8 bit, Y‑full range adjust‑
able ( bit),
Unipolar/bipolar mode
Short‑circuit resistance
< 50 V static
to interference voltage
Short‑circuit resistance
< 500 V/1 ms dynamic
to interference voltage
R
Automatically activated filters and attenuators for
enhanced signal quality.
R
Automatic shut‑off in the case of short circuit,
detection of interference voltage on starting signal
generator.
8.3

Power supply unit

Function
Input voltage
Input frequency
Output voltage
Operating Temperature
8.4

Temperature limits

Characteristic
Function
Storage and transportation
Measurement accuracy
8.5
Humidity
Characteristic
Storage and transportation
Function
Measurement accuracy
8.6

Noise emissions

< 70 dB(A)
8.7

Dimensions and weights

Function
Dimensions H x W x D:
Weight
en
Specification
90 VAC – 264 VAC
47 Hz – 63 Hz
15 V
0 °C – 40 °C
Value/range
5 °C – 40 °C
41 °F – 104 °F
5 °C – 40 °C
41 °F – 104 °F
10 °C – 35 °C
50 °F – 95 °F
Value/range
30 % – 60 %
20% – 80%
30 % – 60 %
Specification
1785 x 680 x 670 mm
91 kg
1 689 989 311
|