30 | FSA 740 Edition | Technical Data
8.1.3
Specification measurement cables
Designation
Connecting cable B+/B–
Clip‑on sensor
Primary connecting cable (UNI
4)
CH1 multi measurement cable
CH2 multi measurement cable
Measurement cable with
voltage divider
Accessory set with:
Test prods
Pick‑off clips
Adapter connectors
Amps clamp 1000 A
Amps clamp 30 A
Accessory set with test prods,
test clips
Secondary measuring sensor
Oil temperature sensor
Connection at the input secondary measuring sensor
1)
1.6 Vpeak ±30% at 100 mA current change within 200 ns with connection at input clip-on sensor (L/C approx. 136 µH/5 nF)
2)
The following applies to voltages >60 V: U[V] x t[ms] ≤ 3200 V*μs, e.g. a voltage of 200 V is not to be applied for longer than 16 μs. The maxi-
3)
mum voltage decreases at frequencies >1 MHz with 20 dB/decade, e.g. sinusoidal 1 MHz max. peak = 200 V/sinusoidal 10 MHz max. peak = 20 V
8.1.4
Oscilloscope
R
Trigger‑System
$
Free run (non‑triggered run ≥ 1 s)
$
Auto (curve output even without trigger)
$
Auto level (as Auto, mid‑signal trigger threshold)
$
Normal (manual trigger threshold, curve output
only with trigger event)
$
Single sequence
R
Trigger edge
$
Edge (pos./neg. on signal)
R
Trigger sources
$
Engine (trigger on cylinder 1 ... 12 with clip‑on
sensor, term. 1, KV sensor)
$
External trigger via term. 1_1 cable or clip‑on sensor
$
CH1/CH2 multi measurement cable
R
Pre‑trigger component
$
0 to 100%, adjustable with mouse
R
Recording modes
$
MaxMin (Peak/Glitchdetect)
$
Interference pulse recording
$
Sample (equidistant sampling)
R
Storage operating and curve output modes
$
Roll mode (single point output) with complete
storage of signals for X deflections ≥ 1 s
$
Legend mode (curve output) with complete stor‑
age of signals for X deflections ≥ 1 ms
$
Normal mode with storage of last 50 curves dis‑
played for X deflections < 1 ms
1 689 989 297
|
2016-05-05
Order number
Measure-
ment
category
1 684 460 195
CAT 0
1 687 224 957
CAT 0
1 684 462 563
CAT 0
1 684 460 258
CAT 0
1 684 460 259
1 687 224 300
CAT 0
1 687 016 118
1 684 485 434/ ... 435
CAT 3
1 684 480 403/ ... 404
CAT 2
1 684 480 125
CAT 2
1 687 224 968
CAT 0
1 687 224 969
CAT 0
1 687 010 153
CAT 0
1 687 224 973
CAT 0
1 687 230 036
CAT 0
Max. measuring
Sensor output
voltage
sensitivity
60 V DC/30 V AC/
42 V ACpeak
30 kV ACpeak
2)
32 V DC/30 V AC/
3)
320 V ACpeak
60 V DC/30 V AC/
3)
42 V ACpeak
60 V DC/30 V AC/
25 V/V
300 V ACpeak/
1000 V DC/AC
1000 V DC/AC
600 V DC/AC
300 V DC/AC
100 mV/A
300 V DC/AC
4 mV/A
30 V DC/ACpeak
30 kV ACpeak
20 mV/kV
5 V
Resistance:
1005 Ω at 25 °C
1530 Ω at 90 °C
R
Measurement system with 8 automatic measurement
functions
$
Mean value
$
Rms value
$
Min
$
Max
$
Peak‑to‑peak
$
Pulse
$
Duty cycle
$
Frequency
R
Selectable signal range
$
Full curve or between cursors
R
Zoom
$
Selectable curve section for horizontal and verti‑
cal enlargement
R
Adjustable cursors with indicators for
$
x1, x2
$
delta x
$
y1 and y2 (channel 1)
$
y1 and y2 (channel 2)
R
Comparison curves
$
Store, load, comment, presetting of scope setup
for live curves
R
Storage functions
$
Scrolling back and forth
$
Search functions e.g. MinMax, duty cycle
Max. output voltage
at the measurement
cable
60 V
5 V
320 V
60 V
20 V
30 V
300 V
30 V
5 V
5 V
60 V
1 V
1)
5 V
Robert Bosch GmbH