Herunterladen Diese Seite drucken

Baumer NE210 Betriebsanleitung Seite 37

Elektronischer vorwahlzähler

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Line 5
Line 6
Line 7
Line 8
Line 9
Line 10
Line 11
Line 12
Leave the programming ➜ Set DIP-switch 4 to „OFF" .
Reprogram the counter to ➜ Press and hold the
the default settings
Downloaded from
www.Manualslib.com
Function enabled in operating mode
0 * Changing of preset value only enabled
1
Changing of scaling factor only enabled
2
Changing of preset value and scaling factor enabled
3
Changing of preset value and scaling factor disabled
Reset key
0 * Reset key
1
Reset key
Reset input function
0 * Counting stop activated during external reset signal.
1
Differentiating reset signal effective with signal edge, no coun-
ting stop.
Start count value 0-999
0 * Start count value 0
Any start count value from 0 - 999
● DIP-switch 1 OFF: output set to preset value.
DIP-switch 1 ON: output set to start count value
Time scale and resolution
0 * 999 s 99 / 100 s
1
99 min 59 s 9/10 s
2
999 min 59 s
3
999 h 59 min
● Only applicable to use as a time counter or time delay relay.
Time delay relay cycle
0 * Operating mode 1: ON delay
1
Operating mode 2: Hold time without stop (can be re-triggered)
2
Operating mode 3: Decay delay
3
Operating mode 4: Hold time with stop
Output signal logic
0 * Normal output signal logic
1
Inverted output signal logic
● In the inverted output logic mode, the outputs are activated
when the power supply is switched on and drop out on preset.
Output signal function
0 * As DIP - switch 2
1
External reset but without pulse signal
mode
instrument on.
manuals search engine
, function enabled in operating mode
activated
disabled
and
www.baumer.com
keys and switching the
NE210
37

Werbung

Kapitel

loading