The scaling factor is an adjustable multiplier, whereby the ingoing
counting pulses are multiplied. The scaling factor can be adjusted
within the range from 0.001 to 99.999. The result of the multiplica-
tion is shown in the display. Only whole-number values are displa-
yed. The remainder of the value is added to the next calculation in
each case.
Change ➜ Hold down the key
change flashes.
➜ Hold down the key
flashing decade is reached.
If a key is not operated within 15 seconds, the current counter status
will automatically be re-displayed.
Store ➜ Press the

5 Programming mode

Operating parameters are set in the programming mode, which is
subdivided into two programming segments, i.e. PRO 0 and PRO 1.
Both segments are described below in their actual order.
Access programming
➔ Set DIP-switch 4 to „ON" .
● Programming of the desired operating parameter is now enabled.
Keying
Key operation is the same in both the PRO 0 and PRO 1 program-
ming segments.
Key
Transfer to the next operating parameter in the programming seg-
1. Function
ment. Accept and acknowledge new value.
2. Function
Key
Function
Select first or next decade position. This will now be displayed
flashing.
Key
When this key is pressed, the display for the decade position con-
Function
cerned runs from 0 to 9 or to the maximum setting value. When the
required number is reached, release the key.
Key
In the case of the preset value, pulse time and start count value,
Function
the display is reset to zero when this key is pressed.
manuals search engine
until the decade position you require to
until the required number within the
key.
www.baumer.com
NE210
35