Herunterladen Diese Seite drucken

Baumer NE210 Betriebsanleitung Seite 36

Elektronischer vorwahlzähler

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

NE210
Line 1
Line 2
Line 3
Line 4
36
Downloaded from
www.Manualslib.com
Programming field PRO 0
Here it is possible to select and modify all operation parameters.
The operation parameters that are disabled for the operator are also
displayed.
Press the key
Current counter status
Preset value
Scaling factor
Programming field PRO 1
All functions and vaules conditioned by the machinery are program-
med here. In programming field PRO 1, 12 programming lines are
displayed in succession.
Default settings are always printed with *.
Decimal point
0 * 99999
1
9999.9
2
999.99
3
99.999
Pulse signal time in seconds (s); adjustable from 0.02 s to 9.99 s
0.00
no output signal
* 0.25 s
0.02...9.99 s
● DIP-switch 2 activates pulse contact of continuous contact.
Counting mode (see 5.1)
0 * Track A and UP / DOWN signal on track B
1
Track A and STOP signal on track B
2
Differential counting, track A adding, track B subtracting (A-B)
3
Totalizing, tracks A and B adding (A+B)
4
Track A 90° B, single evaluation
5
Track A 90° B, twofold evaluation
6
Track A 90° B, fourfold evaluation
(counting frequence max. 5 kHz)
7
Time counter with preset
8
Time delay relay function
Accept preset value
0 * In the case of automatic, external or manual reset
1
Effective immediately with
www.baumer.com
manuals search engine
again
acknowledgement.