Elektronischer vorwahlzähler

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

NPN
B
PNP
B
Programming input logic The signal input logic can be programmed by means of a bridge
Downloaded from
www.Manualslib.com
3.3

Assignment electronic output

The electronic output (terminal 10) is pre-programmed by the
K
factory as an NPN or PNP switching transistor (open collector) in ac-
cordance with the purchase order specification. The output is coded
as a pulse or continuous signal at DIP-switch 2.
E
Output logic
E
NPN
PNP
K
The electronic output is not short-circuit proof.
➔ Assign: terminal 10 accordingly.
3.4

Assignment signal input

Terminals 7 , 8 and 9 are optocoupler inputs that may be triggered by
any PNP or NPN encoder. The required input logic can be assigned at
the connecting terminal by wire jumper (refer also to assigning the
input logic.)
Specification of the inputs
Terminal 7
Terminal 8
NPN
PNP
Max. frequency
Input resistor
Stage Low
Stage High
Terminal 9
NPN
PNP
Min. impulse interval
Input resistor
Stage Low
Stage High
between terminals 11, 12 and 13, in accordance with the table below:
manuals search engine
Max. voltage
+35 V
+24 VDC
Main counter counting input track A
Main counter counting input track B
Active with negative edge
Active with positive edge
10 kHz / 15 Hz
1.65 kΩ
0...0.8 V
14...27 V
Main counter reset
Active with negative edge
Active with positive edge
30 ms
3.3 kΩ
0...1.6 V
14...27 V
www.baumer.com
NE210
Max. current
50 mA
50 mA
29