3. Clean the inlet valve filter using some water.
4. Reconnect the water inlet hose to the tap and the appliance again.

5.5 "Frozen" appliance

If the ambient temperature is lower than 0
proceed as described below:
1. Disconnect the appliance from the mains.
2. Close the water tap.
3. Wash the tap with warm water so you can take the water inlet hose off.
4. Take off the hose and immerse it in warm water.
5. Pour warm water into the drum and wait approx. 10 minutes.
6. Reconnect the water inlet hose to the tap and check, that the water inlet and the
water drain works properly.
7. When you operate the appliance again, the ambient temperature must be higher
than 0

5.5.1 Frost protection

If you have installed the appliance in a place, where the ambient temperature can
easily fall below 0
1. Close the water tap.
2. Remove the water inlet hose from the tap and put the end into a container.
3. Select any programme except the S
4. Press the
approx. 40 seconds.
5. Stop the programme.
6. Connect the water inlet hose again.
Downloaded from
www.Manualslib.com
0
C.
0
C, always empty the inlet and outlet hoses.
How to remove residual water in the water inlet hose:
/
START
PAUSE BUTTON
manuals search engine
0
C and the appliance has been frozen,
programme.
PIN
and allow the programme to operate for
85